Date   

locked Re: Logging Success popup set at 5 seconds, up for 10 seconds

WU9D <mike@...>
 

I'm not into instant gratification, Laurie. I was just trying to ask the question why the prompt was displayed for 10 seconds. And you have answered it, thank you.

I don't ever expect high-priority either. It is your product and at no cost to anyone I do not expect anything. If you do "fix" things, then that's great.

In time I displayed the thing I was referring to. Don't you expect me to lay thing out for you on a silver platter either. I'm not getting paid for troubleshooting.

The worst thing I could do is just leave any "problems" left unsaid. Which is, of course, what I am going to do.


locked Re: WSJT-X 2.5.0-rc1 / JTAlert 2.50.1 blank display #FT8 - update #2 #FT8

ag5pc@...
 

I'm using Norton and now JTAlert has quit working, again. I have added a bi-direction rule to allow UDP 2237 from anywhere. I have installed 2.50.1 and based on a previous, I changed to a multicast address. Now JTAlert is still blank and nothing gets logged. Task manager has JTAlertV2.Manager running. 

Suggestion - publish known good configurations. I tried of one suggestion that worked for a while but doesn't support logging. If I revert to settings that used to work, I loose JTAlert. 

JTAlert Instance       : #1
JTAlert Start Params   : /wsjtx
WSJT-X Window Title    : WSJT-X   v2.4.0   by K1JT, G4WJS, K9AN, and IV3NWV
WSJT-X Command Line    : "C:\WSJT\wsjtx\bin\wsjtx.exe" 
WSJT-X   --rig-name    : 
WSJT-X Config File     : C:\Users\Al\AppData\Local\WSJT-X\WSJT-X.ini
WSJT-X Version         : 
WSJT-X Revision        : 
WSJT-X Spec Op Mode    : None
WSJT-X UDP ID          : 
WSJT-X UDP Port        : 2237
WSJT-X UDP Server      : 224.0.0.1
WSJT-X UDP MCast on LB : True
WSJT-X UDP Max Schema  : 
 
==================================================
UDP Ports used
--------------------------------------------------
JTAlert.exe           : 59689 59409
JTAlertV2.Manager.exe : 55765 55766 55767
JTAlertV2.Decodes.exe : 
 
 
==================================================
Audio output devices
--------------------------------------------------
[1] Speakers (Realtek High Definition Audio)
[2] DAX RESERVED IQ RX 1 (FlexRadio Systems DAX IQ)
[3] DAX RESERVED AUDIO RX 2 (FlexRadio Systems DAX Audio)
[4] DAX RESERVED MIC AUDIO (FlexRadio Systems DAX MIC Audio)
[5] DAX RESERVED IQ RX 4 (FlexRadio Systems DAX IQ)
[6] DAX RESERVED AUDIO RX 1 (FlexRadio Systems DAX Audio)
[7] DAX RESERVED IQ RX 2 (FlexRadio Systems DAX IQ)
[8] DAX RESERVED AUDIO RX 8 (FlexRadio Systems DAX Audio)
[9] DAX RESERVED AUDIO RX 6 (FlexRadio Systems DAX Audio)
[10] DAX RESERVED IQ RX 3 (FlexRadio Systems DAX IQ)
[11] DAX Audio TX (FlexRadio Systems DAX TX)
[12] DAX RESERVED AUDIO RX 3 (FlexRadio Systems DAX Audio)
[13] DAX RESERVED AUDIO RX 4 (FlexRadio Systems DAX Audio)
[14] DAX RESERVED AUDIO RX 7 (FlexRadio Systems DAX Audio)
[15] DAX RESERVED AUDIO RX 5 (FlexRadio Systems DAX Audio)
 
 
==================================================
JTAlertV2.Manager (2.50.1.0) status
(2021-06-13 23:14:09 utc)
--------------------------------------------------
CLR Version      : 5.0.7
NET Framework    : .NET 5.0.7
Architecture     : x64 64bit
--------------------------------------------------
UDP Router       : Initialized : YES (WSJT-X)
Audio            : Initialized : YES (15 output devices)
BandData         : Initialized : YES (started : 58)
Text Msgs        : Initialized : YES (started : 17)
HamSpots         : Initialized : YES
QRZ Xml          : Initialized : YES (AG5PC)
HamQth Xml       : Initialized : YES 
QRZ Log          : Initialized : YES 
HamQth Log       : Initialized : YES 
ClubLog Log      : Initialized : YES 
Eqsl Log         : Initialized : YES 
HrdLog Log       : Initialized : YES 
DXLab DDE        : Initialized : YES
User Alert       : Initialized : YES
Updates Check    : Initialized : YES (started : 3600)
Environment      : Initialized : YES (started : 3600)
Maintenance      : Initialized : YES (started : 3600)
--------------------------------------------------
 


locked Re: Logging with HRD Log V6 (Submode) #HRD

Morris WA4MIT
 

Thanks Laurie will give this a try.
73 Morris WA4MIT


locked Re: Logging with HRD Log V6 (Submode) #HRD

HamApps Support (VK3AMA)
 

On 14/06/2021 8:33 am, Morris WA4MIT via groups.io wrote:
I believe 2.50.1 was suppose to remedy this but the problem is still happening

That is not correct. The fix is in the as yet unreleased 2.50.2, it was never in 2.50.1 as that was the version when the defect was first reported. 2.50.2 should have been out by now but was delayed due to the recent Sound issues induced by a Microsoft patch to NET 5.0.x runtime.

I did release a public beta with a fix a while back when this error was first noted.
see https://hamapps.groups.io/g/Support/message/34923

de Laurie VK3AMA


locked Re: WSJT-X 2.5.0-rc1 / JTAlert 2.50.1 blank display #FT8 - update #FT8

HamApps Support (VK3AMA)
 

On 14/06/2021 7:42 am, ag5pc@... wrote:
uninstalled WSJT-X 2.50-rc1 and installed 2.3.1, uninstalled JTAlert 2.50.1 and installed 2.16.17. None of the apps are / were at "admin" level. This works.

That tells me that your PC protection software is interfering and either blocking or terminating the JTAlertV2.Manager.exe process. All UDP comms is routed via that process. The difference between 2.50.1 and 2.16.17 is the NET framework use to compile the Manager process. Most likely due to the new Manager code your Protection software is disliking the new code. What do you use?

de Laurie VK3AMA


locked Re: Logging with HRD Log V6 (Submode) #HRD

Morris WA4MIT
 

Hi Laurie as always thanks for your tireless work and a great program I use daily. I am using JTDX with Alert 2.50.1and log with HRD 6.7.0.357. I believe 2.50.1 was suppose to remedy this but the problem is still happening. Attached are excerpts from my HRD log and from JTDX to show that JTAlert is still inserting FT8 with submode FT4 into HRD logbook contacts. Un-noticed when uploaded to LOTW they become FT4 contacts not FT8 I have been fighting this happening for couple of weeks now if not longer.
See attached please.

This is from JTDX the saved transmission from a FT8 contact that is logged with submode FT4:
2982 ~ WA4MIT N5EYT -01
20210613_000400.058(0)  Transmitting 14.074 MHz  FT8:  N5EYT WA4MIT R-04                    
20210613_000415 -18  1.8 2983 ~ WA4MIT N5EYT RR73         ^
20210613_000430.140(0)  Transmitting 14.074 MHz  FT8:  N5EYT WA4MIT 73                      
20210613_000438.090(0)  QSO logged: N5EYT

screen shot from my logbook of this contact clearly shows the submode FT4 added.

Thanks 73 Morris wA4MIT









locked Re: WSJT-X 2.5.0-rc1 / JTAlert 2.50.1 blank display #FT8 - update #FT8

ag5pc@...
 

I uninstalled WSJT-X 2.50-rc1 and installed 2.3.1, uninstalled JTAlert 2.50.1 and installed 2.16.17. None of the apps are / were at "admin" level. This works. 



JTAlert Instance      : #1
JTAlert Start Params  : /wsjtx
WSJT-X Window Title   : WSJT-X   v2.3.1   by K1JT, G4WJS, and K9AN
WSJT-X Command Line   : 
WSJT-X   --rig-name   : 
WSJT-X Config File    : C:\Users\Al\AppData\Local\WSJT-X\WSJT-X.ini
WSJT-X Version               : 2.3.1
WSJT-X Revision              : 0e7224
WSJT-X Spec Op Mode          : None
WSJT-X UDP ID                : WSJT-X
WSJT-X UDP Port              : 2237
WSJT-X UDP Server            : 127.0.0.1
WSJT-X UDP MCast on Loopback : True
WSJT-X UDP Max Schema        : 3
 
==================================================
UDP Ports used
--------------------------------------------------
JTAlert.exe           : 54905 51376
JTAlertV2.Manager.exe : 54536 54537 
JTAlertV2.Decodes.exe : 
 
 
==================================================
Audio output devices
--------------------------------------------------
[1] Speakers (Realtek High Definition Audio)
[2] DAX RESERVED IQ RX 1 (FlexRadio Systems DAX IQ)
[3] DAX RESERVED AUDIO RX 2 (FlexRadio Systems DAX Audio)
[4] DAX RESERVED MIC AUDIO (FlexRadio Systems DAX MIC Audio)
[5] DAX RESERVED IQ RX 4 (FlexRadio Systems DAX IQ)
[6] DAX RESERVED AUDIO RX 1 (FlexRadio Systems DAX Audio)
[7] DAX RESERVED IQ RX 2 (FlexRadio Systems DAX IQ)
[8] DAX RESERVED AUDIO RX 8 (FlexRadio Systems DAX Audio)
[9] DAX RESERVED AUDIO RX 6 (FlexRadio Systems DAX Audio)
[10] DAX RESERVED IQ RX 3 (FlexRadio Systems DAX IQ)
[11] DAX Audio TX (FlexRadio Systems DAX TX)
[12] DAX RESERVED AUDIO RX 3 (FlexRadio Systems DAX Audio)
[13] DAX RESERVED AUDIO RX 4 (FlexRadio Systems DAX Audio)
[14] DAX RESERVED AUDIO RX 7 (FlexRadio Systems DAX Audio)
[15] DAX RESERVED AUDIO RX 5 (FlexRadio Systems DAX Audio)
 
 
==================================================
JTAlertV2.Manager (2.16.17.0) status
(2021-06-13 21:39:18 utc)
--------------------------------------------------
NET Framework    : .NET Framework 4.8.4341.0
CLR Version      : 4.0.30319.42000
--------------------------------------------------
UDP Router       : Initialized : YES (WSJT-X)
Audio            : Initialized : YES (15 output devices)
BandData         : Initialized : YES 
Text Msgs        : Initialized : YES (started : 17)
HamSpots         : Initialized : YES
QRZ Xml          : Initialized : YES (AG5PC)
HamQth Xml       : Initialized : YES 
QRZ Log          : Initialized : YES 
HamQth Log       : Initialized : YES 
ClubLog Log      : Initialized : YES 
Eqsl Log         : Initialized : YES 
HrdLog Log       : Initialized : YES 
DXLab DDE        : Initialized : YES
User Alert       : Initialized : YES
Updates Chk      : Initialized : YES
Maintenance      : Initialized : YES
 


locked Re: WSJT talks to N3FJP directly

g4wjs
 

On 13/06/2021 20:37, Dave NT9E wrote:
Laurie,
How do I set up JTAlert so I can receive audible alerts while contesting (VHF) even though JTAlert is not being used to Log the Q's?
Dave,

how can that work if JTAlert does not know which calls you have worked?



--
73
Bill
G4WJS.


locked WSJT talks to N3FJP directly

Dave NT9E
 

Laurie,
How do I set up JTAlert so I can receive audible alerts while contesting (VHF) even though JTAlert is not being used to Log the Q's?


locked Re: JTAlert 2.50.1 NO SOUND

Phil Cooper
 

Hi Paul,

How did you get to the file?

You have to go to Control Panel, and under Programs there is an option to Uninstall a program. Click that, and under Programs and Features, click on Uninstall a program, and wait for it to populate fully.

Close to the top you should see Microsoft Windows Desktop Runtime - 5.0.7.
If you click on that, you should get 3 options in the highlighted bar at the top. They read Organise, Uninstall and Change.
Clicking on Uninstall will delete it, with all the usual warnings etc.

When that has successfully been removed, then you can install 5.0.6 again.

73 de Phil GU0SUP

-----Original Message-----
From: "Paul F6EXV" <f6exv@hotmail.com>
Sent: Sunday, 13 June, 2021 09:57
To: Support@HamApps.groups.io
Subject: Re: [HamApps] JTAlert 2.50.1 NO SOUND

Hi all
I could find the latest version, which is to be deleted.
But I do not have the option to uninstall, only erase, then the
installation of version 5.0.6 does not work.
Any help will be appreciated
73
Paul F6EXV



Le 12/06/2021 à 22:44, HamApps Support (VK3AMA) a écrit :
On 13/06/2021 2:37 am, Neal Keating wrote:
I'm also having the same issue with 2.50.1 - sounds are clipped. 
With Sound On, Call sign window disapears and then re-appears on a
notification.  What is the fix for this?
This has been discussed here on the support forum. A fix (workaround)
has been posted.
See https://hamapps.groups.io/g/Support/message/35446
<https://hamapps.groups.io/g/Support/message/35446>

de Laurie VK3AMA


--
L'absence de virus dans ce courrier électronique a été vérifiée par le logiciel antivirus Avast.
https://www.avast.com/antivirus


locked Re: WSJT-X 2.5.0-rc1 / JTAlert 2.50.1 blank display #FT8

Joe Subich, W4TV
 

On 2021-06-12 11:29 PM, Dave Garber wrote:
Should the operator remove 5.0.7 and teinstall 5.0.6. Was that the
issue as well
No, NET 5.0.7 vs. 5.0.6 only impacts audio.

73,

... Joe, W4TV


On 2021-06-12 11:29 PM, Dave Garber wrote:
Should the operator remove 5.0.7 and teinstall 5.0.6. Was that the issue
as well
On Sat., Jun. 12, 2021, 2:39 p.m. Joe Subich, W4TV, <lists@subich.com>
wrote:


Use Multicast (including a multicast address - not 127.0.0.1).
See the Help Topic "WSJTX UDP Setup" in JT Alert -> Help.

Also, make sure that WSJTX, JT-Alert and Log4OM are *ALL* running
at USER level *NOT* "Run as Administrator".

73,

... Joe, W4TV


On 2021-06-12 12:14 PM, ag5pc@outlook.com wrote:
I just upgraded both WSJT-X and JTAlert to the latest versions. WSJT-X
works fine but JTAlert is blank. See attached screen shot. I get the UDP
error message and I've been through the UDP setup in the help file to no
avail. Per instructions, here is the status:

JTAlert Instance : #1
JTAlert Start Params : /wsjtx
WSJT-X Window Title : WSJT-X v2.5.0-rc1 by K1JT, G4WJS, K9AN, and
IV3NWV
WSJT-X Command Line : "C:\WSJT\wsjtx\bin\wsjtx.exe"
WSJT-X --rig-name :
WSJT-X Config File : C:\Users\Al\AppData\Local\WSJT-X\WSJT-X.ini
WSJT-X Version :
WSJT-X Revision :
WSJT-X Spec Op Mode : None
WSJT-X UDP ID :
WSJT-X UDP Port : 2237
WSJT-X UDP Server : 127.0.0.1
WSJT-X UDP MCast on LB : True
WSJT-X UDP Max Schema :

==================================================
UDP Ports used
--------------------------------------------------
JTAlert.exe : 60764 53991
JTAlertV2.Manager.exe : 61646 61647 61648
JTAlertV2.Decodes.exe :

==================================================
Audio output devices
--------------------------------------------------
[1] Speakers (Realtek High Definition Audio)
[2] DAX RESERVED IQ RX 1 (FlexRadio Systems DAX IQ)
[3] DAX RESERVED AUDIO RX 2 (FlexRadio Systems DAX Audio)
[4] DAX RESERVED MIC AUDIO (FlexRadio Systems DAX MIC Audio)
[5] DAX RESERVED IQ RX 4 (FlexRadio Systems DAX IQ)
[6] DAX RESERVED AUDIO RX 1 (FlexRadio Systems DAX Audio)
[7] DAX RESERVED IQ RX 2 (FlexRadio Systems DAX IQ)
[8] DAX RESERVED AUDIO RX 8 (FlexRadio Systems DAX Audio)
[9] DAX RESERVED AUDIO RX 6 (FlexRadio Systems DAX Audio)
[10] DAX RESERVED IQ RX 3 (FlexRadio Systems DAX IQ)
[11] DAX Audio TX (FlexRadio Systems DAX TX)
[12] DAX RESERVED AUDIO RX 3 (FlexRadio Systems DAX Audio)
[13] DAX RESERVED AUDIO RX 4 (FlexRadio Systems DAX Audio)
[14] DAX RESERVED AUDIO RX 7 (FlexRadio Systems DAX Audio)
[15] DAX RESERVED AUDIO RX 5 (FlexRadio Systems DAX Audio)

==================================================
JTAlertV2.Manager (2.50.1.0) status
(2021-06-12 15:52:23 utc)
--------------------------------------------------
CLR Version : 5.0.7
NET Framework : .NET 5.0.7
Architecture : x64 64bit
--------------------------------------------------
UDP Router : Initialized : YES (WSJT-X)
Audio : Initialized : YES (15 output devices)
BandData : Initialized : YES (started : 58)
Text Msgs : Initialized : YES (started : 17)
HamSpots : Initialized : YES
QRZ Xml : Initialized : YES (AG5PC)
HamQth Xml : Initialized : YES
QRZ Log : Initialized : YES
HamQth Log : Initialized : YES
ClubLog Log : Initialized : YES
Eqsl Log : Initialized : YES
HrdLog Log : Initialized : YES
DXLab DDE : Initialized : YES
User Alert : Initialized : YES
Updates Check : Initialized : YES (started : 3600)
Environment : Initialized : YES (started : 3600)
Maintenance : Initialized : YES (started : 3600)
--------------------------------------------------







locked Re: Decode Window not showing all GRID squares. Need to fix this soonest.

Mark W2OR
 

Thank you Laurie, and thank you Joe and John.
I've since slapped myself and had two cups of coffee.
73


locked Re: JTAlert 2.50.1 NO SOUND

Paul F6EXV
 

Hi all
I could find the latest version, which is to be deleted.
But I do not have the option to uninstall, only erase, then the installation of version 5.0.6 does not work.
Any help will be appreciated
73
Paul F6EXV



Le 12/06/2021 à 22:44, HamApps Support (VK3AMA) a écrit :
On 13/06/2021 2:37 am, Neal Keating wrote:
I'm also having the same issue with 2.50.1 - sounds are clipped.  With Sound On, Call sign window disapears and then re-appears on a notification.  What is the fix for this?

This has been discussed here on the support forum. A fix (workaround) has been posted.
See https://hamapps.groups.io/g/Support/message/35446

de Laurie VK3AMA


Garanti sans virus. www.avast.com


locked Re: WSJT-X 2.5.0-rc1 / JTAlert 2.50.1 blank display #FT8

Dave Garber
 

Should the operator remove 5.0.7 and teinstall 5.0.6.  Was that the issue as well


On Sat., Jun. 12, 2021, 2:39 p.m. Joe Subich, W4TV, <lists@...> wrote:

Use Multicast (including a multicast address - not 127.0.0.1).
See the Help Topic "WSJTX UDP Setup" in JT Alert -> Help.

Also, make sure that WSJTX, JT-Alert and Log4OM are *ALL* running
at USER level *NOT* "Run as Administrator".

73,

    ... Joe, W4TV


On 2021-06-12 12:14 PM, ag5pc@... wrote:
> I just upgraded both WSJT-X and JTAlert to the latest versions. WSJT-X works fine but JTAlert is blank. See attached screen shot. I get the UDP error message and I've been through the UDP setup in the help file to no avail. Per instructions, here is the status:
>
> JTAlert Instance       : #1
> JTAlert Start Params   : /wsjtx
> WSJT-X Window Title    : WSJT-X   v2.5.0-rc1   by K1JT, G4WJS, K9AN, and IV3NWV
> WSJT-X Command Line    : "C:\WSJT\wsjtx\bin\wsjtx.exe"
> WSJT-X   --rig-name    :
> WSJT-X Config File     : C:\Users\Al\AppData\Local\WSJT-X\WSJT-X.ini
> WSJT-X Version         :
> WSJT-X Revision        :
> WSJT-X Spec Op Mode    : None
> WSJT-X UDP ID          :
> WSJT-X UDP Port        : 2237
> WSJT-X UDP Server      : 127.0.0.1
> WSJT-X UDP MCast on LB : True
> WSJT-X UDP Max Schema  :
>
> ==================================================
> UDP Ports used
> --------------------------------------------------
> JTAlert.exe           : 60764 53991
> JTAlertV2.Manager.exe : 61646 61647 61648
> JTAlertV2.Decodes.exe :
>
> ==================================================
> Audio output devices
> --------------------------------------------------
> [1] Speakers (Realtek High Definition Audio)
> [2] DAX RESERVED IQ RX 1 (FlexRadio Systems DAX IQ)
> [3] DAX RESERVED AUDIO RX 2 (FlexRadio Systems DAX Audio)
> [4] DAX RESERVED MIC AUDIO (FlexRadio Systems DAX MIC Audio)
> [5] DAX RESERVED IQ RX 4 (FlexRadio Systems DAX IQ)
> [6] DAX RESERVED AUDIO RX 1 (FlexRadio Systems DAX Audio)
> [7] DAX RESERVED IQ RX 2 (FlexRadio Systems DAX IQ)
> [8] DAX RESERVED AUDIO RX 8 (FlexRadio Systems DAX Audio)
> [9] DAX RESERVED AUDIO RX 6 (FlexRadio Systems DAX Audio)
> [10] DAX RESERVED IQ RX 3 (FlexRadio Systems DAX IQ)
> [11] DAX Audio TX (FlexRadio Systems DAX TX)
> [12] DAX RESERVED AUDIO RX 3 (FlexRadio Systems DAX Audio)
> [13] DAX RESERVED AUDIO RX 4 (FlexRadio Systems DAX Audio)
> [14] DAX RESERVED AUDIO RX 7 (FlexRadio Systems DAX Audio)
> [15] DAX RESERVED AUDIO RX 5 (FlexRadio Systems DAX Audio)
>
> ==================================================
> JTAlertV2.Manager (2.50.1.0) status
> (2021-06-12 15:52:23 utc)
> --------------------------------------------------
> CLR Version      : 5.0.7
> NET Framework    : .NET 5.0.7
> Architecture     : x64 64bit
> --------------------------------------------------
> UDP Router       : Initialized : YES (WSJT-X)
> Audio            : Initialized : YES (15 output devices)
> BandData         : Initialized : YES (started : 58)
> Text Msgs        : Initialized : YES (started : 17)
> HamSpots         : Initialized : YES
> QRZ Xml          : Initialized : YES (AG5PC)
> HamQth Xml       : Initialized : YES
> QRZ Log          : Initialized : YES
> HamQth Log       : Initialized : YES
> ClubLog Log      : Initialized : YES
> Eqsl Log         : Initialized : YES
> HrdLog Log       : Initialized : YES
> DXLab DDE        : Initialized : YES
> User Alert       : Initialized : YES
> Updates Check    : Initialized : YES (started : 3600)
> Environment      : Initialized : YES (started : 3600)
> Maintenance      : Initialized : YES (started : 3600)
> --------------------------------------------------
>








locked Re: JTAlert 2.50.1 NO SOUND

Neal Keating
 

Laurie, I found issue - downgraded to .Net 5.06 and sound is working fine. thanks!


On Sat, Jun 12, 2021 at 4:45 PM HamApps Support (VK3AMA) <vk3ama.ham.apps@...> wrote:
On 13/06/2021 2:37 am, Neal Keating wrote:
I'm also having the same issue with 2.50.1 - sounds are clipped.  With Sound On, Call sign window disapears and then re-appears on a notification.  What is the fix for this?

This has been discussed here on the support forum. A fix (workaround) has been posted.
See https://hamapps.groups.io/g/Support/message/35446

de Laurie VK3AMA


locked Re: JTAlert 2.50.1 NO SOUND

Neal Keating
 

Hi Laurie - Thanks for the update.  I followed the procedure but the problem remains - it did not resolve the issue.  Any other ideas?

Thanks, Neal (KC2O)

On Sat, Jun 12, 2021 at 4:45 PM HamApps Support (VK3AMA) <vk3ama.ham.apps@...> wrote:
On 13/06/2021 2:37 am, Neal Keating wrote:
I'm also having the same issue with 2.50.1 - sounds are clipped.  With Sound On, Call sign window disapears and then re-appears on a notification.  What is the fix for this?

This has been discussed here on the support forum. A fix (workaround) has been posted.
See https://hamapps.groups.io/g/Support/message/35446

de Laurie VK3AMA


locked Re: Decode Window not showing all GRID squares. Need to fix this soonest.

HamApps Support (VK3AMA)
 

On 13/06/2021 3:48 am, Mark W2OR via groups.io wrote:
I've apparently missed something obvious.

The other party has never sent their grid in any of the received decodes for the current JTAlert session.

JTAlert does cache any decoded grid so that it is able to display grid/distance/bearing information for non-grid decodes. Some stations never tx their grid so will never show that grid-based information.

de Laurie VK3AMA


locked Re: Logging Success popup set at 5 seconds, up for 10 seconds

HamApps Support (VK3AMA)
 

On 13/06/2021 3:39 am, WU9D wrote:
When "Auto clear triggered Alert entity after logging" is selected on any alerts the logging prompt window is displayed for 10 seconds, not 5 as set. If all of the auto clear options are cleared the logging prompt reverts to the selected value.

Can the program be designed such that the selected prompt display value is actually used when auto clear options are selected?

Terminology is important. You're referring to the Logging Success popup, it is not a Logging Prompt. JTAlert does not have a Logging Prompt window/popup, WSJT-X/JTDX have a Logging Prompt window. The subject of this message thread has been updated to reflect this.

The 5 second versus 10 second display time is by design and has been that way since JTAlert 2.16.13 (29-Aug-2020). From the release notes...
  Changes:

    - Logging Success Popop: The display time for this popup is increased to 10
       seconds (default is 5 seconds) if one or more of the Wanted Alerts is set
       to have their "Needed" settings automatically adjusted when logging a QSO
       as per the new "Auto clear triggered Alert entity after logging" feature.
       The increase display time is to provide sufficient time to review what
       changes have been automatically applied to the internal Alert Database.

Until now there have been no complaints about this increased display time when Alerts are set to auto-clear.

I will make that a user settable option in future release, it has been added to the todo-list. But don't expect instant gratification, this type of change is not high-priority and is not likely to be implemented any time soon, sorry.

de Laurie VK3AMA


locked Re: JTAlert 2.50.1 NO SOUND

HamApps Support (VK3AMA)
 

On 13/06/2021 2:37 am, Neal Keating wrote:
I'm also having the same issue with 2.50.1 - sounds are clipped.  With Sound On, Call sign window disapears and then re-appears on a notification.  What is the fix for this?

This has been discussed here on the support forum. A fix (workaround) has been posted.
See https://hamapps.groups.io/g/Support/message/35446

de Laurie VK3AMA


locked Re: Logging prompt set at 5 seconds, up for 10 seconds

WU9D <mike@...>
 

When "Auto clear triggered Alert entity after logging" is selected on any alerts the logging prompt window is displayed for 10 seconds, not 5 as set. If all of the auto clear options are cleared the logging prompt reverts to the selected value.

Can the program be designed such that the selected prompt display value is actually used when auto clear options are selected?